显示标签为“introduction”的博文。显示所有博文
显示标签为“introduction”的博文。显示所有博文

2015年12月22日星期二

How to solve inflexible rotation problem of conveyor roller?

To ensure accuracy during conveyor roller manufacturing process 
Such as the inner hole precision of punch bearing housing should reach grade 3, dimensional tolerance,coaxial degree and ovality of the pipe body two ends must conform to the national standard,can not exceed the tolerance.
Sealing and lubrication
in addition to ensure the quality of manufacture, also require better lubrication materials, such as lithium base grease which can improve the bearing lubrication performance, this is very necessary to prolong the service life of roller.
Bearing seat adopts labyrinth seal structure of centripetal ball bearing supporting and plastic sealing ring, which can guarantee reasonable bearing stress of roller during operation,but also ensure good dust prevention effect, small resistance, and convenient installation and easy maintenance, it can effectively reduce the conveyor operation cost at the same time. 

solve inflexible rotation problem of conveyor roller

2015年10月5日星期一

Introduction of Motor IP Grade: The meaning of the second number

0: no special protection
1: drip-proof: vertical drop of water will not directly enter into the motor.
2:15 degrees angle drip proof: within a range of 15 degrees angle, water drop will not directly enter into the motor.
3: 60 degrees angle water spray proof: within a range of 60 degrees angle, water-spray will not directly enter into the motor.

electric vibrator motor.
4: water splash proof: splash water in any direction will not bring harmful effects to motor.
5: water spray proof: spray water in any direction will not bring harmful effects to motor.
6: water waves or strong water spray proof: furious waves or strong water spray will not bring harmful effects tomotor.
7: water immersion proof: motor immersed in the water under a stipulated pressure and time, the water inflow will not bring harmful effects.

Electric vibratory motor with flange

2015年9月30日星期三

Introduction of Motor IP Grade :The Meaning of First Number

Motor IP (INGRESS PROTECTION) grade system is drafted by IEC (INTERNATIONAL ELECTROTECHNICAL COMMISSION ).IP grade is composed of two numbers, the first number represents for anti-invasion grade of external objects and dust, the second the number shows that the sealing degree of anti- invasion of moisture and water, if the number is greater, the degree of protection will be higher.
0: no special protection
1: it can prevent external objects with solid diameter larger than 50 mm entering into the casing.
2: it can prevent external objects with solid diameter larger than12 mm entering into the casing.
3: it can prevent external objects with solid diameter larger than 2.5 mm entering into the casing.
4: it can prevent external objects with solid diameter larger than 1 mm entering into the casing.
5: protection against dust, it can prevent dust from entering to affect the normal operation of the product, and prevent dust contacting the inner casing or parts.
6: sealing against dust, it can completely prevent dust from entering into the casing and prevent the dust contacting the inner casing or parts.
view vibratory motor

The Introduction of Vibration Motor

Customer reference list
CUSTOMER REFERENCE LIST (YEAR 2012-2014)
NO.EQUIPMENTVENDOR'S SCOPE OF SUPPLY  
  PROJECT LOCATIONQUANTITYTIME
47Vibration motorKenya2 Sets20140926
42Vibration motorIndonesia16 Sets20140500


► Brief introduction:

Vibration motor is the general exciting vibration source of all kinds of vibrating machines such as vibrating screen, vibrating feeder, vibrating conveyor, vibrating flask shaker, vibrating crusher, vibrating molding machine, vibrating sand mixer, vibrating buffing machine, block-proof device, vibrating test-bed, etc.

► Features :
1. High efficiency running
2. Stable vibrating frequency
3. Dust-proof and water-proof
4. Strong resistance to vibration, large kinetic motion
5. Exciting force could be infinitely variable controlled.

►Application
Vibrating motor can be widely used in power plant, building materials, grain, coal, mine, metallurgy, chemical industry, light industry, casting, railway, port and other industries. The products have been well received by our customers. 

2015年9月26日星期六

The Using of Conveyor Rainproof Cover

Customer reference list
CUSTOMER REFERENCE LIST (YEAR 2012-2014)
NO. EQUIPMENT VENDOR'S SCOPE OF SUPPLY QUANTITY TIME
PROJECT LOCATION
2Conveyor CoverBolivia350 Pieces20120322
3Conveyor CoverTaiwan,China100 Pieces20120400
38Conveyor CoverMadagascar1182 Pieces20140400
48Conveyor CoverArabia And The United Arab Emirates485 Pieces20141015

► Brief introduction:Conveyor rainproof cover is made by color steel plate.It is used to protect transported material, conveyor belting, idlers and structure from rain, wind, dust during transportation and reducing material loss.Conveyor cover makes operation and transportation safe and reliable,it also plays an important role to purify the environment.

► Application
Anti-rain cover is suitable for 500/650/800/1000/1200/1400/1600/1800/2000mm width belt conveyor in power station, cement plant, steel mill, chemical plant, port, dock, mine, coal plant etc.

► Features
1.Anti-rain,dust and wind
2.Safe to Handle and easy to Maintain
3.Light weight,simply assembly and dismantling
4.Long service life
5.Easy access for belt and idler repair

► Advantage

    1. Proven strength, adaptability and low maintenance. 
    2. Lightweight elements simplify assembly, dismantling and re-use. 
    3. Zinc coating of the sections and support bands combine to provide long service life. 
    4. Designed to provide easy access for belt and idler repair. 
    5. Effective length 900mm; can be overlap joint. 
    6. Thickess 0.5~1mm; 
    7. Fixed type, whole open-close type, particle open -close type, deviation conveyor hood etc;

► Selection condition


    1.What is the conveying material and its physical characteristics? such as bulk density, feeding size, temperature, mositure content etc.
    2. What is the processing capacity of the elevator?
    3. What is the lifting height of the elevator (distance between inlet and outlet)?